EasyManuals Logo

Honeywell Galaxy Dimension series User Manual

Honeywell Galaxy Dimension series
306 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #102 background imageLoading...
Page #102 background image
Galaxy Dimension Installer Manual
6-28
Table 6-4. Default Codes
* The authorization code is a secondary system manager code but is not programmed by default.
Engineer Code
Engineer access is enabled via menu 48.1. This menu is only available to type 3.6 users.
The engineer code can only modify the engineer PIN.
The engineer code cannot assign, modify or delete the manager or user codes;
On accessing engineering mode, any group that is set becomes inaccessible to the engineer. The
set groups cannot be assigned to zones, outputs and any other functions permitting group
allocation;
While engineer mode is accessed, all tampers are disabled, however, all constantly alert zone
types — PA zone types, 24 Hour, Security, Fire — remain active.
The engineer banner is shown on all keypads while engineer mode is being accessed; the
message ENGINEER MODE is displayed;
Entry to the engineer mode must be authorized by a valid type 3.6 user (refer to option 48 = ACCESS
AUTHORIZATION). The engineer code must then be entered within five minutes of the option being ena-
bled. A single entry of the engineer code directly accesses engineer mode, without activating an engineer
tamper alarm; ENGINEER MODE is displayed on the keypad. If the engineer code is not entered within
the five minute period, the code is invalid and an Insufficient Access Rights message is displayed on the
keypad. Once the engineer mode has been accessed, there is no time limit on the period that the engineer can
remain in the mode.
NOTE: Dual entry of the engineer code in a system requiring user authorization does not give access to
engineer mode.
Default Codes
The Galaxy system provides four default codes: Manager, Engineer, Remote and Authorization User. Refer to
the following table:
42 - Codes (cont’d)
Galaxy No. of Codes
Manager Engineer Remote Authoriz ation*
Default PIN User No. Default PIN User No. Default PIN User No. Default PIN User No.
GD-48 100 12345 98 112233 99 543210 100 - 97
GD-96 250 12345 248 112233 249 543210 250 - 247
GD-264 1000 12345 998 112233 999 54321 1000 997
GD-520 1000 12345 998 112233 999 543210 1000 - 997

Table of Contents

Other manuals for Honeywell Galaxy Dimension series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Dimension series and is the answer not in the manual?

Honeywell Galaxy Dimension series Specifications

General IconGeneral
ModelGalaxy Dimension series
UsersUp to 250
PartitionsUp to 8
Operating Temperature-10°C to +55°C
CompatibilityHoneywell Galaxy accessories and peripherals

Related product manuals