Galaxy Dimension Installer Manual
6-14
Options 17 - 19
Option 17 – Silent Part
Selecting this option sets all zones that have the part attribute enabled. It starts a normal timed exit procedure
but exit sounders are not activated. In the event of an alarm occuring during a Silent Part set (e.g. fire alarm),
normal operation will be re-instated.
When group mode is enabled (Menu option 63.1), setting of a group using Silent Part set will not affect the
operation of any of the other group setting options.
NOTE: The zones must be closed to allow the system to silent set. If any zones are open, then the Exit
Time Reset feature (detailed previously) is activated.
Unsetting from Menu option 17 will still give a double beep.
Option 18 – Home Set
The Home Set option either fully sets or part sets the system. The system is:
fully set if the exit time is manually terminated via a Final or Push-Set zone operation;
part set if the exit time is allowed to expire.
Option 19 – All Set
All Set allows a timed set of groups assigned to the user code without offering the choice of which groups are
to be set. No group choice is offered. The groups that are set when this option is selected is determined by the
keypad group restriction (refer to option 58.7 = KEYPADS.Groups):
If there is no keypad group restriction then all of the groups assigned to the user are set — as long as
there is at least one common group assigned to the keypad.
If there is a group restriction on the setting keypad, then only the groups that are common to both the user
and the keypad on which the menu option is selected are set. For example, a user assigned groups 1, 2, 3,
and 4 selecting the All Set option on a keypad assigned groups 2 and 3 will only set groups 2 and 3.

Table of Contents

Other manuals for Honeywell Galaxy Dimension series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Dimension series and is the answer not in the manual?

Honeywell Galaxy Dimension series Specifications

General IconGeneral
ModelGalaxy Dimension series
UsersUp to 250
PartitionsUp to 8
Operating Temperature-10°C to +55°C
CompatibilityHoneywell Galaxy accessories and peripherals