Galaxy Dimension Installer Manual
6-48
the panel records in the event log the message REM ABORT to indicate that the connection was unexpectedly
terminated. The default timeout period is 10 minutes.
4 = Conn. Retry
If the attempt to initiate a remote servicing call fails, the panel can be programmed to do repeat dial attempts.
There are three further options:
1 = Retry Interval
The dial attempts can be programmed to occur from 0-60 minutes. Setting the value to 0 disables the feature
The default setting is 30 minutes.
2 = Retry Duration
The length of time that the panel tries to do a remote servicing call can be programmed from 0-24 hours.
setting the value to 0 disables the feature. The default setting is 6 hours.
3 = Redial Mode
In the event of a remote servicing session terminating unexpectedly, the panel enters one of the three program-
mable modes that follow.
0 = Off
The panel does not try to re-establish a connection.
1 = Retry
The panel initiates a remote servicing call to re-establish a connection. The retries will be as per option
47.4.4.1 (Retry Interval) and 47.4.4.2 (Retry Duration).
2 = Direct
The panel access mode changes to allow direct access for 30 minutes. This mode operates as per
option 47.1=Service when Direct Access is selected.
5 = Control Upload
This option controls whether a connection is established when only engineer or user programming data is
uploaded. This feature has three options.
1 = Eng Prog
Only initiates a connection when engineering programming has been modified.
2 = User Prog
Only initiates a connection when user programming has been modified.
3 = Either
Initiates a connection when either engineering or user programming has been modified.
6 = Remote Maint
This option controls the mode for automatically initiating communications for remote routine inspection and
47 - Remote Access (contd)

Table of Contents