Galaxy Dimension Installer Manual
6-103
77 Bell Test
This output activates when Bell Test is selected via menu 32. This causes the bell and strobe output to
activate. This output is normally used to activate a relay to cut power to the bell.
78 Comms Test (Pulse)
This output is used for remote routine inspection, via the downloader software. When a remote inspection is
carried out, this output will activate for 10 seconds in order to trigger the test input of an external comms
device.
79 Door Prop
This output activates when a door is held open for longer than the programmed time and an Open Timeout
occurs (Option 69).
80 Door Force
This output activates when a door is forced open without authorization and an alarm occurs.
81 Listen-in
This output activates after an alarm activation and an audio transmission is in progress.
53 - Program Outputs (cont’d)

Table of Contents

Other manuals for Honeywell Galaxy Dimension series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Dimension series and is the answer not in the manual?

Honeywell Galaxy Dimension series Specifications

General IconGeneral
ModelGalaxy Dimension series
UsersUp to 250
PartitionsUp to 8
Operating Temperature-10°C to +55°C
CompatibilityHoneywell Galaxy accessories and peripherals

Related product manuals