Galaxy Dimension Installer Manual
6-132
3 = Call Back
Up to five telephone numbers can be programmed into this option. Remote Servicing requests the Galaxy
to call back to one of the numbers.
NOTES:
1. If Manager Authorize is selected as the Remote Access Mode, then the ISDN module can only
make outgoing calls - it is disabled from answering all incoming calls.
2. If Call Back is selected, then access to the Galaxy is denied unless the call back option in Remote
Servicing is used to initiate the connection.
56.3.10 Alarm Monitoring
This is identical to the Microtech format communications (56.1.3). This option is used to allow alarms to be
dialled to a PC with Alarm Monitoring software loaded as well as to an ARC using the Primary and/or Sec-
ondary formats.
56.3.11 Backup Module
This option allows another module to become the primary communication module if a line fail is detected on
the ISDN module. There are 6 options:
1 = Off; 2 = Ext Telecoms; 3 = Ext RS232; 4 = Ethernet; 5 = Int Telecom; 6 = Int RS232 1.
56 - Communications (cont’d)

Table of Contents

Other manuals for Honeywell Galaxy Dimension series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Dimension series and is the answer not in the manual?

Honeywell Galaxy Dimension series Specifications

General IconGeneral
ModelGalaxy Dimension series
UsersUp to 250
PartitionsUp to 8
Operating Temperature-10°C to +55°C
CompatibilityHoneywell Galaxy accessories and peripherals