Galaxy Dimension Installer Manual
6-135
56 - Communications (cont’d)
The SIA format is capable of transmitting the Galaxy events indicated in Appendix D of this manual.
Refer to Appendix C of this manual for the detailed breakdown of the SIA event structure for each level.
On selecting the SIA format, the keypad prompts for the required SIA level to be entered, there are five SIA
levels available:
Level 0 (default) – basic event information with 4 digit account numbers
1 – as level 0 plus 6 digit account numbers
2 – as level 1 but with event modifiers
3 – as level 2 but with text descriptors
4 – as level 3 but also enables the SIA control command feature (refer option 08 SIA control)
1 = Trigger Events
When the SIA level has been selected press the ent key. The keypad displays the first trigger event and it’s
On/Off status (see table 25 for the list of available triggers, and Appendix B for the events which are
controlled by each trigger). The triggers control the events, which are transmitted. If the trigger is set to On,
any events logged, which are controlled by the trigger will be transmitted. If the trigger is set to Off, the
events controlled by the trigger will not be transmitted. Step through the trigger events using the A and B
keys.
1 = Status
To modify the trigger on/off status select the trigger to be modified using the A and B keys and press the
ent key. To program the status to On press 1, to set it to Off press 0. Alternatively use the A/B keys to
toggle between On and Off. To accept the new status, press the ent key. This will automatically return
the display to the previous menu level.
Programming the SIA format with groups enabled
If groups have been enabled on the system (refer to option 63.1), then the SIA format menu alters slightly to
support the independent event trigger programming for each group.
1 = Trigger Events
On selecting the SIA level the menu enters the Trigger Events option. Press the ent key to display the first
trigger event; the keypad shows the trigger, the trigger status and the groups assigned.
To modify the trigger event select the required event using the A and B keys and press the ent key. The
1=Status option is then displayed. If the status requires to be modified press the ent key.
1 = Status
To program the status to On press 1, to set it to Off press 0. Alternatively use the A/B keys to toggle
between On and Off. To accept the new status, press the ent key. This will automatically return the
display to the previous menu level.
2 = Groups
If groups have been enabled on the system (refer option 63.1), then the groups can be assigned to each
event trigger. This means that the events have to occur in assigned groups before they are signalled. To
modify the groups assigned to a specific trigger press the ent key from the 2=Groups menu option. The
display will show the groups and indicate whether it is assigned (Y) or not assigned (N) to the group. To
assign or unassign a group from a specific trigger press the number key corresponding to the group

Table of Contents

Other manuals for Honeywell Galaxy Dimension series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Dimension series and is the answer not in the manual?

Honeywell Galaxy Dimension series Specifications

General IconGeneral
ModelGalaxy Dimension series
UsersUp to 250
PartitionsUp to 8
Operating Temperature-10°C to +55°C
CompatibilityHoneywell Galaxy accessories and peripherals

Related product manuals