EasyManuals Logo

Honeywell Galaxy Dimension series User Manual

Honeywell Galaxy Dimension series
306 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #214 background imageLoading...
Page #214 background image
Galaxy Dimension Installer Manual
6-140
2 = Mode
This option controls access authorization and whether the remote session is initiated from (Panel or PC).
1 = Direct Access
This permits access at any time (in conjunction with Access period). Access is initiated from Remote Servic-
ing. Once access is authorized/initiated, uploading, downloading and remote servicing can begin.
2 = Manager Authorize
This option requires authorization from the site manager in order to gain remote access to the Galaxy panel.
There are two methods that the manager can use to enable access to the Galaxy via Remote servicing.
Timed Access – Remote Servicing must access the Galaxy panel within 40 minutes of this option being ena-
bled by the manager (Option 47.1.2.0). Once connected there is no time limit on the access period. On
terminating the connection, Remote Servicing can reaccess the system within a 15 minute period of the termi-
nation.
Call Back – the manager instructs the Galaxy panel to initiate a connection to the Remote Servicing PC (Use
option 47.1.2.1) by selecting one of the Call back IP addresses programmed into the system
1 = Call Back IP 1-5
There are 5 possible IP address/Port number destinations, which can be programmed for Remote Servic-
ing access. This allows communication with up to five different Remote Servicing locations.
1 = IP Address
Enter the IP address of the PC running the Remote Servicing application
2 = Port No.
Enter the Port Number allocated to Remote Servicing on the PC (Default is 10001)
56.4.04 = Autotest
An engineer test can be automatically transmitted to the receiving station at programmed intervals.
1 = Start Time
The engineer uses this option to enter the time that the first engineer test is transmitted. Subsequent engineer
test transmissions are sent periodically. The frequency of each test is controlled by the 2=Interval option.
2 = Interval
This option determines the period between automatic engineer test transmissions following the Start Time. The
programmable range is 0-99 hours.
56.4.05 = Engineer Test
An engineer test can be sent on each of the transmission paths once the appropriate IP address/port no, and
account numbers have been programmed into the system. This allows the installation engineer to ensure that
56 - Communications (cont’d)

Table of Contents

Other manuals for Honeywell Galaxy Dimension series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Dimension series and is the answer not in the manual?

Honeywell Galaxy Dimension series Specifications

General IconGeneral
ModelGalaxy Dimension series
UsersUp to 250
PartitionsUp to 8
Operating Temperature-10°C to +55°C
CompatibilityHoneywell Galaxy accessories and peripherals

Related product manuals