Galaxy Dimension Installer Manual
6-153
2 = B-key
The programming of the B key is identical to that of the A key.
3 = Buzzer Mimic
This option determines whether the keypad buzzer mimics the function of the programmed keypad output
(refer to option 53 = PROGRAM OUTPUTS). The default function of the keypad output is Entry/Exit
Horn and the default Mimic defaults to On, therefore the keypad buzzer operates as an Entry/Exit Horn at
factory setting.
To disable the keypad buzzer from mimicking the output select 0 = Off.
4 = Backlighting
This option determines when the keypad backlighting switches on and off.
0 = always off,
1 = always on (default),
2 = on when the system is unset;
off when the system is set;
switches on when the keys are pressed,
3 = on during setting and unsetting;
switches on when keys are pressed;
switches off after keypad timeout and when menu is exited,
4 = switches on when keys are pressed;
switches off after keypad timeout and when menu is exited.
5 = Keypad Mute
This option allows the bleep which normally accompanies a valid keypress to be disabled. This features
improves security and reduces tampering with the keypad when it is located in a public place.
When the Mute option is set to 1 = On, whenever the keypad banner is displayed the keypresses are silent,
there are no s displayed as each key is pressed and the keypad backlighting remains off. As soon as a valid
code is entered the keypad returns to normal operation - the keys are accompanied by bleeps and the
backlighting switched on. The Mute option defaults to disabled (0 = Off).
Keypad Disable
A keypad may be disabled by programming the address of the keypad as a link destination (refer to menu
option 54 - Links). When the source of the link is activated the keypad does not respond to any keypress,
however, the LCD, keypad buzzer and any keypad output device acts as normal.
58 - Keypad (cont’d)

Table of Contents

Other manuals for Honeywell Galaxy Dimension series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Dimension series and is the answer not in the manual?

Honeywell Galaxy Dimension series Specifications

General IconGeneral
ModelGalaxy Dimension series
UsersUp to 250
PartitionsUp to 8
Operating Temperature-10°C to +55°C
CompatibilityHoneywell Galaxy accessories and peripherals

Related product manuals