Galaxy Dimension Installer Manual
6-165
1 = Outputs
Any of the available output types can be assigned to the custom zone. On selecting this attribute the
01=BELLS output type is displayed along with it status; the default status is disabled. The status indicates the
conditions under which the custom zone activates the output. To assign the output type status press the # key,
this toggles between each of the status settings:
1. Disabled the output is not activated by the custom zone,
2 Set the output is activated by the custom zone only when the system is set,
3 Unset the output is activated by the custom zone only when the system is unset,
4. Set/Unset the output is activated by the custom zone when the system is both set and unset.
Select the output types to be assigned by pressing the A and B keys or by entering the number of the required
output type and assign the required status. When all of the output types have been selected, press the esc key
to return the previous menu level.
For a full list of output types refer to option 53 = Program Outputs.
2 = Status
The Status attribute determines the system conditions that custom zone is operational in. The four Status
attributes are:
1. Unset activates an alarm when the system is unset,
2. Entry/Exit activates an alarm when the system is setting and unsetting,
3. Part Set activates an alarm when the system is part set,
4. Full Set activates an alarm when the system is full set.
The default for each of the Status attributes is disabled. To enable the zone to activate an alarm, select the
required Status attribute using the A or B keys and press the # key; the display indicates that a custom zone
activation while the system is in the selected Status will create an Alarm condition and switch on the assigned
outputs.
NOTE: The custom zone can be operational in all four Status conditions if required.
64 - Assemble Zones (cont’d)

Table of Contents

Other manuals for Honeywell Galaxy Dimension series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Dimension series and is the answer not in the manual?

Honeywell Galaxy Dimension series Specifications

General IconGeneral
ModelGalaxy Dimension series
UsersUp to 250
PartitionsUp to 8
Operating Temperature-10°C to +55°C
CompatibilityHoneywell Galaxy accessories and peripherals

Related product manuals