Galaxy Dimension Installer Manual
6-167
Assemble Zone Example:
Assemble a zone that:
activates Bells outputs when the system is set,
activates Link-A outputs when the system is unset,
generates an alarm condition when the system is part and full set,
does not generate an alarm condition during the setting and unsetting procedure,
acts as a terminator when the system is setting,
logs all activation (in both set and unset states).
Programming:
(Assuming factory default settings)
1. Select option 64 = ASSEMBLE ZONES; press the ent key,
2. Select custom zone (1 = Custom-A, 2 = Custom-B); press the ent key,
3. Outputs is displayed. Press the ent key to select this option,
4. Bells is displayed. Press the # key. Set is displayed,
5. Enter 51. Link-A is displayed. Press the # key. Set is displayed,
6. Press the # key. Unset is displayed,
7. Press the esc key. Outputs is displayed,
8. Press the A key. Status is displayed. Press the ent key to select this option,
9. Unset Disabled is displayed,
10. Press the A key. Entry/ Exit Disabled is displayed,
11. Press the A key. Part Set Disabled is displayed,
12. Press the # key. Part Set Alarm is displayed,
13. Press the A key. Full Set Disabled is displayed,
14. Press the # key. Full Set Alarm is displayed,
15. Press the esc key. Status is displayed,
16. Press the A key. Setting is displayed. Press the ent key to select this option,
17. Begin Set Disabled is displayed,
18. Press the A key. Sets System Disabled is displayed,
19. Press the # key. Sets System Enabled is displayed,
20. Press the esc key. Setting is displayed,
21. Press the A key. Log is displayed. Press the ent key to select this option,
22. Log Disabled is displayed,
23. Press the # key. Log Entry/Exit is displayed,
24. Press the # key. Log 24 Hours is displayed,
25. Press the esc key three times to return to the 64 = ASSEMBLE ZONES display.
64 - Assemble Zones (cont’d)

Table of Contents

Other manuals for Honeywell Galaxy Dimension series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Dimension series and is the answer not in the manual?

Honeywell Galaxy Dimension series Specifications

General IconGeneral
ModelGalaxy Dimension series
UsersUp to 250
PartitionsUp to 8
Operating Temperature-10°C to +55°C
CompatibilityHoneywell Galaxy accessories and peripherals

Related product manuals