6-170
65 - Timers (cont’d)
W01MON ON 08:30W01MON ON 08:30
W01MON ON 08:30W01MON ON 08:30
W01MON ON 08:30
4 = Holiday Period
This is the holiday period programmed in 45.2.1. Timer Control.Holidays.Modify Dates. Up to 32 holiday
periods can be viewed with this option.
5 = Holiday Schedule
This is an alternative schedule that is used if option 45.2. Timer Control.Holidays is activated. The system
defines a selection of holiday dates (65.1.4) and then a schedule of times can be used on those dates under
this option. Up to 67 holiday schedules can be selected.
6 = Pattern Day
The Pattern Day can only be allocated by the engineer. This option determines the programmed timers that
are effective when the Weekend Day option (45.6.1) is selected by the user; the timers of the selected
Pattern Day are adopted by the days selected for weekend work.
On selecting this option the programmed Pattern Day is displayed; the default is 1 = MON. Use the A or B
keys to select the required day or days and press the ent key to accept the programming and return to the
previous menu level:
1 = MON
2 = TUE
3 = WED
4 = THU
5 = FRI
4 To enter a new timer program for W01 do the following:
Press ent to select the timer.
Press the A or B keys to select the day (MON to SUN).
Press the # key to select the status ON or OFF.
Press the number keys (0-9) to select the first time (4 digit 24 hour format) on the top row.
Press ent to accept the programming. The following typical window is displayed:
5 To program the OFF time on the bottom row repeat step 4. The following typical window is displayed:
W01MON ON 08:30W01MON ON 08:30
W01MON ON 08:30W01MON ON 08:30
W01MON ON 08:30
MON OFF 17:00 MON OFF 17:00
MON OFF 17:00 MON OFF 17:00
MON OFF 17:00
6 Press the esc key three times to escape from the Timers option.
NOTE: The Timer Status can be switched On and Off by users via option 45 = TIMER CONTROL.

Table of Contents

Other manuals for Honeywell Galaxy Dimension series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Dimension series and is the answer not in the manual?

Honeywell Galaxy Dimension series Specifications

General IconGeneral
ModelGalaxy Dimension series
UsersUp to 250
PartitionsUp to 8
Operating Temperature-10°C to +55°C
CompatibilityHoneywell Galaxy accessories and peripherals

Related product manuals