Galaxy Dimension Installer Manual
6-174
During the Lockout period, the group can not be unset unless an alarm has been activated in the group. In the
event of an alarm occurring during the Lockout period, any valid type 2.3 (or above) code assigned to the
group in alarm may be used to unset and/or reset the group. If multiple locked-out groups are in an alarm
condition entry of a single valid code (type 2.3 or above with access to the relevant groups) cancels the alarms
and unsets the activated groups.
The group can only be manually unset once in each Lockout Off period. If no Lockout times are pro-
grammed, the group may be unset at any time.
Codes are not affected by Lockout, and can be used to gain access to the menus and to manually set the
group.
Programming Lockout
There are two stages to programming the Lockout function. These are options 6 = Lockout Status and
7 = Lockout Schedule of the Autoset programming menu:
6 = Lockout Status
The lockout status has to be set to On before the lockout schedule will function.
0 = Off (default)
1 = On
7 = Lockout Schedule
This option allocates the automatic lockout time schedule OFF (Unlock) and On (Lockout) for the selected
group. Up to 67 weekly schedules are available which are programmed in 65.1=Weekly Schedule.
65 - Timers (cont’d)