EasyManuals Logo

Honeywell Galaxy Dimension series User Manual

Honeywell Galaxy Dimension series
306 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #259 background imageLoading...
Page #259 background image
Galaxy Dimension Installer Manual
6-185
69 - Access Control (cont’d)
7 = Security
This option determines when and how a door can be locked and unlocked for access.
1 = Nightlock
This allows a time schedule to be allocated to determine when access to the door will be blocked. Up to
67 weekly time schedules can be programmed. Setting the schedule to 00 disables the function.
2 = Unlock Time
This allows a time schedule to be allocated to determine when the door will be unlocked to provide unre-
stricted access. Up to 0-67 weekly time schedules can be programmed. Setting the schedule to 00 disa-
bles the function.
Dual Mode
This defines if access at a door requires dual authority or not via the assigned keypad. The options are:
0 = Disabled
A card or a Pin is required to gain access.
1 = Card and Card
Two cards are required to gain access.
2 = Card and Pin
A card and a Pin from the same user are required to gain access.
8 = Menu Recall
This means that a card-held function can be assigned to the reader. A user is able to do a card-held function
even if they do not have card-held priviledges themselves.
1 = Menu Function
Depending on the level of access granted in Option 68, Menu Access, the user can hold their card at a
compatible reader for three seconds to activate a single menu function selected from the available list. A
new option is assigned by pressing the A or B keys until the required option is displayed or by entering the
option number directly and then pressing the ent key to accept the selection. Assigning a Double asterisk
(**) to the menu function makes it not used.
2 = Menu Mode
This determines whether a card held function can be used to access the reader. There is one option which
is 1 = Card Held.
2 = Keypad
This assigns a specific keypad address to work in conjunction with a MAX. This keypad is used to display
the menu action assigned in 1 = Menu Function.

Table of Contents

Other manuals for Honeywell Galaxy Dimension series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Dimension series and is the answer not in the manual?

Honeywell Galaxy Dimension series Specifications

General IconGeneral
ModelGalaxy Dimension series
UsersUp to 250
PartitionsUp to 8
Operating Temperature-10°C to +55°C
CompatibilityHoneywell Galaxy accessories and peripherals

Related product manuals