Galaxy Dimension Installer Manual
B-5
Ev SIA Event Galaxy Log Galaxy Log Event Ev Type Galaxy Contact
Description Event Description Trigger ID Event
DK Access Lockout DCM EVENT Invalid Card Reader Lockout USER 16.LOG 421
10.SETTING
17.MAXTAG
DT Door propped DOOR PROP MAX - Door left open MOD. 4.SECURITY 426
E - System Trouble
ER Mod Removed REMOVED Module Removed MOD TAMPER 532
ET RF NVM Fail RF MEM! RF NVM RAM Fail MOD TAMPER 333
F - Fire
FA Fire Alarm FIRE+ Fire zone alarm ZONE 6.FIRE 110
FB Fire Bypass OMITTED Fire zone ommitted ZONE 8.OMIT 573
FORCEOMT+ Force omit after rearm ZONE 8.OMIT 573
FJ Fire Troub rest LOW RES- Restor zone resistance ZONE 15.TROUBL 380
HIGH RES- Restor zone resistance ZONE 15.TROUBL 380
FR Fire Restoral FIRE- Fire zone restored ZONE 6.FIRE 110
18.ZN RESTO
FT Fire Trouble LOW RES+ Low resistance on zone ZONE 15.TROUBL 380
HIGH RES+ High resistance on zone ZONE 15.TROUBL 380
FU Fire Unbypass FORCE OMT- Unomitted after rearm ZONE 8.OMIT 573
FX Fire Test FIRE Fire zone tested ZONE NOT SENT None
SOAK TEST Soak test fire zone act ZONE NOT SENT None
G - Gas (Custom SIA - See Note 2)
GA Alarm Note 1 zone in alarm ZONE 5.CUS ZON Note 1
GB Bypass OMITTED zone ommitted ZONE 8.OMIT Note 1
FORCEOMT+ Force omit after rearm ZONE 8.OMIT Note 1
GJ Trouble Rest LOW RES- Restor zone resistance ZONE 15.TROUBL Note 1
HIGH RES- Restor zone resistance ZONE 15.TROUBL Note 1
GR Alarm Restore Note 1 zone restored ZONE 5.CUS ZON Note 1
18.ZN RESTO
GT Trouble LOW RES+ Low resistance on zone ZONE 15.TROUBL Note 1
HIGH RES+ High resistance on zone ZONE 15.TROUBL Note 1
GU Unbypass FORCE OMT- Unomitted after rearm ZONE 8.OMIT Note 1
H - Holdup
HA Holdup Alarm PA SILENT+ PA Silent zone alarm ZONE 1.PA/DURE 122
PA DEL/SL+ PA Delay Sil.zone alarm ZONE 1.PA/DURE 122
DURESS Duress with code USER 1.PA/DURE 121
PA UNSET+ PA Unset zone alarm ZONE 1.PA/DURE 122
HB Holdup Bypass OMITTED Holdup zone omitted ZONE 8.OMIT 573
FORCEOMT+ Force omit after rearm ZONE 8.OMIT 573
HJ Hold Troub rest LOW RES- Restor zone resistance ZONE 15.TROUBL 380
HIGH RES- Restor zone resistance ZONE 15.TROUBL 380
HR Hold Restoral PA SILENT- PA Silent zone restored ZONE 1.PA/DURE 122
18.ZN RESTO
PA DEL/SL- PA Delay Sil.zone rest. ZONE 1.PA/DURE 122
18.ZN RESTO
PA UNSET- PA Unset zone restored ZONE 1.PA/DURE 122
18.ZN RESTO
HT Holdup Trouble LOW RES+ Low resistance on zone ZONE 15.TROUBL 380
HIGH RES+ High resistance on zone ZONE 15.TROUBL 380
HU Hold Unbypass FORCE OMT- Unomitted after rearm ZONE 8.OMIT 573
Event Codes (cont’d)