Galaxy Dimension Installer Manual
B-8
Ev SIA Event Galaxy Log Galaxy Log Event Ev Type Galaxy Contact
Description Event Description Trigger ID Event
P - Panic
PA Panic Alarm PA+ PA zone alarm ZONE 1.PA/DURE 120
DELAY ALM+ PA Delay zone alarm ZONE 1.PA/DURE 120
PB Panic Bypass OMITTED PA zone omitted ZONE 8.OMIT 573
FORCEOMT+ Force omit after rearm ZONE 8.OMIT 573
PJ Pan Troub rest LOW RES- Restor zone resistance ZONE 15.TROUBL 380
HIGH RES- Restor zone resistance ZONE 15.TROUBL 380
PR Panic Restoral PA- PA zone restored ZONE 1.PA/DURE 120
18.ZN RESTO
DELAY ALM- PA Delay zone restored ZONE 1.PA/DURE 120
18.ZN RESTO
PT Panic Trouble LOW RES+ Low resistance on zone ZONE 15.TROUBL 380
HIGH RES+ High resistance on zone ZONE 15.TROUBL 380
PU Panic Unbypas FORCE OMT- Unomitted after rearm ZONE 8.OMIT 573
Q - Assist (Custom SIA - see note 2)
QA Alarm Note 1 zone in alarm ZONE 5.CUS ZON Note 1
QB Bypass OMITTED zone ommitted ZONE 8.OMIT 573
FORCEOMT+ Force omit after rearm ZONE 8.OMIT 573
QJ Trouble Rest LOW RES- Restor zone resistance ZONE 15.TROUBL 380
HIGH RES- Restor zone resistance ZONE 15.TROUBL 380
QR Alarm Restore Note 1 zone restored ZONE 5.CUS ZON Note 1
18.ZN RESTO
QT Trouble LOW RES+ Low resistance on zone ZONE 15.TROUBL 380
HIGH RES+ High resistance on zone ZONE 15.TROUBL 380
QU Unbypass FORCE OMT- Unomitted after rearm ZONE 8.OMIT 573
R - Remote,Log,Test
RB REM LOG USER NONE 0
REM RESET USER NONE 0
REM ID USER NONE 0
REM COPY USER NONE 0
REM OVRWR USER NONE 0
REM MSG USER NONE 0
COPY SITE MODULE NONE 0
OVWR SITE MODULE NONE 0
RC Relay closed LINK- Link zone closed ZONE 16.LOG 150
LOG- Log zone closed ZONE 16.LOG 150
LOG DELAY- Log delay zone closed ZONE 16.LOG 150
CUSTOM A- Zone closed(Non alarm) ZONE 16.LOG 150
CUSTOM B- Zone closed(Non alarm) ZONE 16.LOG 150
EXITGUARD- Exitguard zone closed ZONE 16.LOG 150
Event Codes (cont’d)