Galaxy Dimension Installer Manual
6-12
There are five zone types which vary from the standard Omit Zones operation:
Vibration Zones — if the omitted zone is a Vibration zone, then all zones (in all groups) programmed as
this type are block omitted. The Vibration zones remain omitted until they are manually reinstated.
Unsetting the system does not reinstate Vibration zones.
ATM1/2/3/4 Zones — a single ATM zone type can be omitted for the duration of the period entered in
the ATM Timeout parameter (option 51.39). The ATM Delay parameter (option 51.38) determines
the delay before ATM zones are omitted following the entry of one of the ten ATM Codes.
Entry of a code allows the user to omit one of the ATM zone types. Once omitted, the initiating keypad
indicates the number of minutes remaining until the selected ATM zones are reintroduced to the system. A
warning is given ten and five minutes before the zones are reinstated. The omit time may be extended indefi-
nitely by re-entering an ATM Code. Outputs programmed as ATM1/2/3/4 are active when the respective
ATM zone type is omitted, and remain active until the zone type is reinstated.
Refer to option 52 = PROGRAM ZONES for details on the operation of Vibration and ATM zone types.
Manually Reintroducing Omitted Zones to the System
Selecting the OMIT ZONES option; using the A or B keys, select the omitted zone to be reinstated. Press
the # key toggle the omit status of the required zone. The display indicates the new omit status.
Normal Setting with Omitted Zones
Initiate the full or part setting routine. The system starts to set; the display indicates that zones have been
omitted. The zone remains omitted until the system is unset (with the exception of Vibration and ATM zones).
11 - Omit Zones (cont’d)

Table of Contents

Other manuals for Honeywell Galaxy Dimension series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Dimension series and is the answer not in the manual?

Honeywell Galaxy Dimension series Specifications

General IconGeneral
ModelGalaxy Dimension series
UsersUp to 250
PartitionsUp to 8
Operating Temperature-10°C to +55°C
CompatibilityHoneywell Galaxy accessories and peripherals

Related product manuals