Scan the barcodes below to change the message length. Refer to Message Length Description
(page 82) for additional information. Minimum and Maximum lengths = 1-2435. Minimum
Default = 1, Maximum Default = 2435.
The scanner can automatically format the output from any GS1 data carrier to emulate what
would be encoded in an equivalent GS1-128 or GS1 DataBar symbol. GS1 data carriers include
UPC-A and UPC-E, EAN-13 and EAN-8, ITF-14, GS1- 128, and GS1 DataBar and GS1
Composites. (Any application that accepts GS1 data can be simplified since it only needs to
recognize one data carrier type.)
If GS1-128 Emulation is scanned, all retail codes (U.P.C., UPC-E, EAN8, EAN13) are expanded
out to 16 digits. If the AIM ID is enabled, the value will be the GS1- 128 AIM ID, ]C1 (see
Symbology Charts on page 200).
If GS1 DataBar Emulation is scanned, all retail codes (U.P.C., UPC-E, EAN8, EAN13) are
expanded out to 16 digits. If the AIM ID is enabled, the value will be the GS1-DataBar AIM ID,
]em (see Symbology Charts on page 200).
If GS1 Code Expansion Off is scanned, retail code expansion is disabled, and UPC- E expansion
is controlled by the UPC-E0 Expand (page 118) setting. If the AIM ID is enabled, the value will
be the GS1-128 AIM ID, ]C1 (see Symbology Charts on page 200).
If EAN8 to EAN13 Conversion is scanned, all EAN8 barcodes are converted to EAN13 format.
Default = GS1 Emulation Off.