Reinstall the ITB
Use this procedure to verify that the ITB is correctly reinstalled.
1. Use the control panel to print a Diagnostics page. See the complete version of the English service
manual.
2. Verify that rows one through four, columns A through I (callout 1) contain hexadecimal numbers.
If these rows and columns are all zero, ensure that the calibration sensor was correctly reinstalled.
The sensor must be correctly positioned and fit securely against the chassis before the mounting
screws are installed. See
Figure 1-93 Remove the ITB (2 of 6) on page 64 and Figure 1-92
Remove the ITB (1 of 6) on page 64.
Figure 1-98 Reinstall the ITB
HP Color LaserJet PRO 400
Diagnostics Page
Calibration Information
Color Density
Power-On Calibration : 15 Minutes
Calibration Timing: 48 Hours
C M Y K
Contrast 0 0 0 0
Highlights 0 0 0 0
Midtones 0 0 0 0
Shadows 0 0 0 0
Parameters
04
1
ENWW
Removal and replacement procedures
67