EasyManuals Logo

HP StorageWorks P9000 - Disk Arrays User Guide

HP StorageWorks P9000 - Disk Arrays
193 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #25 background image
Journal volumes consist of two areas: one area is used for storing journal data, and the other
area is used for storing metadata.
Journal volumes support all RAID configurations that are supported by P9500. Journal volumes
also support all physical volumes that are supported by P9500.
Customized volumes can be used for journal volumes.
See system requirements and specifications in “Requirements and specifications” (page 17) for
more information.
Planning pair volumes
The following information is provided to help you prepare volumes for configuration. Also, see
system requirements and specifications in “Requirements and specifications” (page 17) for more
information.
The emulation and capacity for the S-VOL must be the same as the P-VOL
When the S-VOL is connected to the same host as the P-VOL, the S-VOL must be defined to
remain offline.
Continuous Access Journal supports the LUN Expansion feature, which allows you to configure
a LUSE volume by using 2 to 36 sequential LDEVs. If two LUSE volumes are assigned to a
Continuous Access Journal pair, the capacity and configuration of the Continuous Access
Journal S-VOL must be the same as the Continuous Access Journal P-VOL. For example, when
the P-VOL is a LUSE volume in which 1-GB, 2-GB, 3-GB volumes are combined in this order,
the S-VOL must be a LUSE volume in which 1-GB, 2-GB, 3-GB volumes are combined in this
order. In addition, RAID1, RAID5, and RAID6 can coexist in the LUSE volume.
Continuous Access Journal supports the Virtual LUN feature, which allows you to configure
custom-size LUs that are smaller than standard-size LUs. When custom-size LUs are assigned
to a Continuous Access Journal pair, the S-VOL must have the same capacity as the P-VOL.
For details about Virtual LUN feature, see HP StorageWorks P9000 Provisioning for Open
Systems User Guide.
Identify the volumes that will become the P-VOLs and S-VOLs. Note the port, group ID (GID),
and LUN of each volume. This information is used during the initial copy operation.
You can create multiple pairs at the same time. For details, see (page 53).
When you create a Continuous Access Journal pair, you will have the option to create only
the relationship, without copying data from primary to secondary volumes. You can use this
option only when the contents of the primary and secondary data volume are completely the
same.
Maximum number of pairs allowed
P9500 has a limit on the number of pairs that can be created. Therefore, it is necessary to calculate
the maximum number of pairs on the P9500 storage system. The maximum number is limited
according to the following:
1. The number of cylinders in the volumes, which must be calculated.
2. The number of bitmap areas required for Continuous Access Journal data and journal volumes.
This is calculated using the number of cylinders.
Planning pair volumes 25

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

HP StorageWorks P9000 - Disk Arrays Specifications

General IconGeneral
Form FactorRack-mountable
ModelHP StorageWorks P9000
TypeDisk Array
CategoryStorage
Drive TypeSSD, SAS
RAID LevelsRAID 0, 1, 5, 6, 10
Host InterfaceFibre Channel, FCoE, iSCSI
ConnectivityFibre Channel, FCoE, iSCSI
Cache MemoryUp to 512 GB
ControllersDual controllers
Management SoftwareHP StorageWorks Command View
Redundancycontrollers, power supplies, and fans
Operating Humidity20 to 80% relative humidity, non-condensing