Shenzhen Hpmont Technology Co., Ltd Appendix A Parameters
HD30 Series Inverters User Manual 165
No. Name Range
Factory
Default
Unit
Modified
attributes
Setting
F16.00
Display panel with
potentiometer function
selection
0: Reserved
1: Upper limit frequency
setting source
2: Frequency setting source
3: Auxiliary frequency
reference
4: Process PID reference
5: Process PID feedback
6: Process PID regulating
upper limit
7: Process PID regulating
lower limit
8: Motor overheating signal
input
0 1 ×
F16.01
Analogue input AI1
function selection
2 1 ×
F16.02
Analogue input AI2
function selection
5 1 ×
F16.03
Analogue input AI3
function selection
0 1 ×
F16.04
Analogue input AI4
function selection
0 1 ×
F16.05
Analogue input AI1
bias
-100.0100.0% 0.0% 0.1%
F16.08
Analogue input AI2
bias
-100.0100.0% 0.0% 0.1%
F16.11
Analogue input AI3
bias
-100.0100.0% 0.0% 0.1%
F16.14
Analogue input AI4
bias
-100.0100.0% 0.0% 0.1%
F16.06
Analogue input AI1
gain
-10.0010.00 1.00 0.01
F16.09
Analogue input AI2
gain
-10.0010.00 1.00 0.01
F16.12
Analogue input AI3
gain
-10.0010.00 1.00 0.01
F16.15
Analogue input AI4
gain
-10.0010.00 1.00 0.01
F16.07
Analogue input AI1
filtering time
0.0110.00s 0.05s 0.01s
F16.10
Analogue input AI2
filtering time
0.0110.00s 0.05s 0.01s
F16.13
Analogue input AI3
filtering time
0.0110.00s 0.05s 0.01s
F16.16
Analogue input AI4
filtering time
0.0110.00s 0.05s 0.01s
F16.17
Maximum input pulse
frequency
0.050.0kHz 10.0kHz 0.1kHz
F16.18
Input pulse filtering
time
0500ms 10ms 1ms