Chapter 6 Function Introduction Shenzhen Hpmont Technology Co., Ltd
78 HD30 Series Inverters User Manual
6.2.8 Group F07 Wobble Operation Parameters
The wobble operation process is shown as below:
First, the inverter accelerates to the preset frequency of wobble operation (F07.02) within the
acceleration time and then waits for certain time (F07.03). Hinterher the inverter transits to the
central frequency of the wobble operation as per the acceleration time, and ultimately start wobble
operation according to the preset wobble amplitude (F07.04), jump frequency (F07.05), wobble
cycle (F07.06) and the rise time of wobble operation (F07.07) until it receives a stop command and
stops as per the deceleration time.
The process is shown in figure:
No. Name Description Range
factory setting
F07.00
Wobble operation selection
0,10
0: Disabled.
1: Enabled.
F07.03
Acc.
time
F07.06
Dec.time
Rising time: F07.06 x F07.07
F07.02
Running frequency
Lower limit of frequency F
L
Central frequency F
set
Upper limit of frequency F
H
F
H
= F
set
+ F
w
F
L
= F
set
- F
w
Amplitude F
w
= Fset x F07.04
Jump freq. = F
w
x F07.05
Run command
Stop command
Time

Table of Contents

Other manuals for hpmont HD30 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the hpmont HD30 Series and is the answer not in the manual?

hpmont HD30 Series Specifications

General IconGeneral
Brandhpmont
ModelHD30 Series
CategoryInverter
LanguageEnglish

Related product manuals