Appendix C Communication Protocol Shenzhen Hpmont Technology Co., Ltd
198 HD30 Series Inverters User Manual
10. Give the fault reset signal to the address 2 of Slave
Address Parameter Register address Register content Checksum
0x02 0x06 0x32 0x00 0x11 0x00 0x8B 0x11
Corresponding answer frame:
Address Code Register address Register content Checksum
0x02 0x06 0x32 0x00 0x11 0x00 0x8B 0x11
11. Functional parameter management and read the lower limit of F02.03
Address Code Subfunction code Data Checksum
0x02 0x42 0x00 0x01 0x02 0x03 0x69 0x57
Corresponding answer frame:
Address Parameter Subfunction code Data Checksum
0x02 0x42 0x00 0x01 0x00 0x00 0x28 0x36