Chapter 5 Function Introduction
MONT20 User Manual V1.6 27
5.2.4 F03: OD Curve Parameter
Refer to 6.2.4 Distance Control OD Running, on page 46 for details.
Ref. Code Function Description Setting Range [Default]
OD start distance/OD start time
At distance control: Start distance (unit: pulse number).
At speed control: Start time (unit: ms).
F03.02 OD Acc. time 0.1 - 99.9 [1.3s]
Define the Acc. time from zero frequency to Max. frequency during OD process.
F03.03 OD speed 0.00 - F00.04 [20.00Hz]
Define the high running speed (frequency) during OD process.
F03.04 OD Dec. point position 50.0 - 90.0 [65.0% door width]
When pulse number ≥ F03.04 × door width, door motor decelerates from F03.03 (OD speed) to F03.06
(creeping speed at OD ending).
The bigger F03.04 is set, the shorter F03.04 is to complete door open.
F03.05 OD Dec. time 0.1 - 99.9 [1.4s]
Define the Dec. time from Max. frequency (F00.07) to zero frequency.
F03.06 Creeping speed at OD ending 0.00 - 15.00 [3.00Hz]
Define the low creeping speed (frequency) of door motor during OD process.
F03.07 OD limit point position 80.0 - 99.9 [95.0% door width]
When door position pulse > F03.07 × door width, door motor outputs complete OD signal.
F03.08 High-speed area of re-opening curve 10.0 - 90.0 [90.0% door width]
F03.08 defines high-speed area of re-opening curve at re-opening.
• May improve the re-opening efficiency.
Example:
F03.08 = 70.0% and 100 - 70 = 30, it means that when the door position is within the range of 0 - 30%, it will
automatically accelerate to high speed when the door is re-opened; When the door position is within the
range of 30 - 100%, the operating curve will be automatically converted according to the current position
when the door is re-opened.