Chapter 5 Function Introduction
28 MONT20 User Manual V1.6
5.2.5 F04: CD Curve Parameters
Refer to 6.2.5 Distance Control CD Running, on page 47 for details.
Ref. Code Function Description Setting Range [Default]
F04.00
CD start distance/CD start time
0 - 9999 [0]
At distance control: Start distance (unit: pulse number).
At speed control: Start time (unit: ms).
F04.01
CD start speed
0.00 - 15.00 [4.00Hz]
F04.02 CD Acc. time 0.1 - 99.9 [1.4s]
Define the Acc. time from zero frequency to Max. frequency during CD process.
F04.03 CD speed 0.00 - F00.07 [18.00Hz]
Define the high running speed (frequency) during CD process.
F04.04 CD Dec. point position 50.0 - 90.0 (door width) [62.0%]
When pulse number ≥ (1 - F04.04) × door width, door motor will decelerate from F04.03 (CD speed) to F04.06
(creeping speed at CD ending).
The bigger F04.04 is set, the shorter F04.04 is to complete door close.
F04.05 CD Dec. time 0.1 - 99.9 [1.3s]
Defines the Dec. time from Max. frequency to zero frequency.
F04.06 Creeping speed at CD ending 0.00 - 15.00 [3.00Hz]
Define the low creeping speed (frequency) of door motor during CD process.
F04.07 Door vane acting position at CD ending/running time at CD ending
creeping speed
1 - 5000 [0]
Distance control: Starting distacnce (unit: pulse number).
When pulse number F04.07, the related process of executing CD ending door vane action.
Speed control: Running time at CD ending creeping speed (unit: ms).
F04.08 Door vane action speed at CD ending 0.00 - 15.00 [0.00Hz]
Define the door motor running speed (frequency) of door vane action position within range of F04.07 during
CD process.
F04.09 CD limit point position 1 - 500 [60]
When the door position is within the CD limit point, door motor will output fully close signal of door.
F04.10 CD ending speed of Asyn. 0.00 - 5.00 [0.00Hz]
F04.11 CD ending range of Asyn. door vane CD/running time of CD ending
Asyn. door vane action speed
0 - 5000 [0]
Distance control: Starting distance (unit: pulse number).
When pulse numberF04.11 setting pulse number, CD ending door vane action will be processed.
Speed control: Running time of CD ending Asyn. door vane action speed (unit: ms).