Chapter 5 Function Introduction
36 MONT20 User Manual V1.6
5.2.9 F08: Demo Running Parameter
Ref. Code Function Description Setting Range [Default]
F08.00
Demonstrate the retention time of running complete OD
1.0 - 999.9 [2.0s]
F08.01 Demonstrate the retention time of running complete CD 1.0 - 999.9 [2.0s]
F08.02
Demonstrate the running times records
0 - 65535 [0]
F08.03 Demonstrate the nominated running times 0 - 65535 [0]
Demonstrate the record of running times.
F08.02 is saved at power off automatically. When completely re-power on, value of F08.02 adds one by each
door opening.
The demo mode is used in demonstrating and aging test. It starts by pressing (RUN key) or (JOG
key) or receiving OD/CD command from external terminal.
After starting, the door motor opens/closes the door at low speed, after completely open/close, it
opens/closes door according to running curve.
Time starts to count after completey door open. When time of F08.00 is finished, it runs in opposite CD
automatically; After finishing door closing, the CD retention time reaches F08.01, and opens the door in
forward direction. This process is repeated and not stop until pressing (STOP key) or the running
times > F08.03.
Value of F08.02, F08.03 can be modified.