Chapter 5 Function Introduction
40 MONT20 User Manual V1.6
Ref. Code Function Description Setting Range [Default]
F10.22
Auxiliary parameter 3
00000 - 11111 [0]
Unit: Slow signal command
0: Used with the OD/CD command.
1: The slow signal is separately turned off.
Note: When set it to 1 instead, as long as the slow signal
is valid, a slow closing action is performed.
Ten: Power off function
0: Does not work.
1: Works.
Note: When set it to 1 instead, as long as the bus voltage
is detected to be lower than 200V, the door motor
performs a slow closing action.
Hundred: Switch door command mode
0: Non-pulse triggered.
1: Pulse triggered.
Thousand: Pre-operation detection output phase
loss
0: Not detected.
1: Detect.
Ten thousand: Complete OD output
0: The door open output is only related to the door
position.
1: The door command cancels the door open
output signal.
F10.23
Auxiliary parameter 4
00 - 11 [0]
Unit: Language selection
0: Chinese.
1: English.
Note: This parameter is used to externally operate the keypad MT70-LCD-D operation voice.
Ten: Keypad UP/DN start door width self-learning
0: Keypad UP/DN is allowed to start self-learning by 5s at the same time.
1: Keypad UP/DN is not allowed to start self-learning by 5s at the same time.
F10.24 - F10.29 Factory debug parameters
5.3 Group y: Manufacturer Parameters
Group y is manufacturer parameters group for debugging at the factory before delivery.