Indicator Status Meaning Diagnosis
UID button/
indicator
Steady blue The server is
being located.
NOTE
● The UID
button/
indicator helps
identify and
locate a server.
You can turn
on or
o the
UID indicator
by manually
pressing the
UID button or
running a
command on
the iBMC CLI or
remotely
controlling the
UID indicator
on the iMana
200 or iBMC
WebUI.
● You can hold
down the UID
button for 4 to
6 seconds to
reset the iMana
200 or iBMC.
Blinking blue
The server is
distinguished
from multiple
servers that have
also been located.
O The server is not
being located or is
not powered on.
Step 2 View iMana 200 or iBMC system event logs (SELs) to locate faults.
Step 3 Check the status indicators of the components.
● Table 5-5, Table 5-6, Table 5-7, Table 5-8, Table 5-9, and Table 5-10
describe the meanings of the SAS/SATA drive status indicator, NVMe drive
status indicator, M.2 FRU indicator, PSU status indicator, network port
indicator, and FlexIO card status indicator, and the corresponding handling
procedures.
● Table 5-11 describes the meanings of the indicators for each module of the
RH5885 V2, RH5885 V3, and RH5885H V3, and the corresponding handling
procedures.
● Table 5-12 describes the meanings of the indicators for each module of the
RH8100 and X6800, and the corresponding handling procedures.
● Table 5-13 describes the meanings of the aggregation network port
indicators on the X6000, X6800, and X6800 V5, and the corresponding
handling procedures.
● Table 5-14, Table 5-15, and Table 5-16 describe the meanings of the MM910
management module indicator, E9000 fan module indicator, and E9000 switch
module indicator, and the corresponding handling procedures.
● Table 5-17 and Table 5-18 describe the meanings of the fan module
indicator and network port indicator on the Atlas 800 training server (model
9010), and the corresponding handling procedures.
Huawei Servers
Troubleshooting 5 Diagnosing and Rectifying Faults