b. Browse or search iManager NetEco 6000 V600R009 Version Mapping,
obtain
iManager NetEco 6000 V600R009 Version Mapping
from Support
> Documentation > Network Energy > Fusion Modular Data Center >
iManager NetEco 6000. Based on the actual NE types and versions to
download the mediation software installation package.
For carriers:
a. Log into Huawei's carrier support website https://support.huawei.com.
b. Browse or search iManager NetEco 6000 V600R009 Version Mapping,
obtain
iManager NetEco 6000 V600R009 Version Mapping
from Support
> Software > Network Energy > Data Center Facility > Fusion Modular
Data Center > iManager NetEco 6000. Based on the actual NE types
and versions to download the mediation software installation package.
Step 2 Choose System > Conguration > Adapter Management from the main menu.
Step 3 Click Upload. On the displayed Upload Adapter Package page, click + and select
the
les to be uploaded.
NO TE
A maximum of 50 adapter packages can be uploaded at one time.
Step 4 Click Upload to upload the les.
Step 5 Select the NE mediation packages to be installed on the Adapter Management
page and click Install. Then click Yes in the displayed dialog box. The length of
time used for the installation is related to the number of adaptation layers. Please
wait patiently for the installation to complete.
----End
5.3.12.1.8 Adding a Management Domain
This section describes how to
congure managed domains.
Prerequisites
You have logged in to the NetEco client by web browser.
The management domain adaptation layer has been precongured or
installed.
Context
The management domains include Park, Building, Room, ContainerDC, Subnet,
NetecoSite, FusionModule500, Modular, Room-ShapeNode, and Building-
ShapeNode. You are advised to plan the
aliation before conguring the
managed domains.
To create management domain, note that:
You can create Park, Building, ContainerDC, Room, Subnet, NetecoSite,
FusionModule500, Modular, Room–ShapeNode, and Building–ShapeNode
under Root.
You can create Building, Building–ShapeNode, ContainerDC, Room and
Room–ShapeNode under Park.
FusionModule500 Smart Mini Data Center
User Manual 5 Power-On Commissioning
Issue 01 (2020-11-30) Copyright © Huawei Technologies Co., Ltd. 165

Table of Contents

Questions and Answers: