l If the ONU connects to the OLT not through a physical-layer transmission device, such as
a switch, they are connected through a GE or 10GE port. If the ONU connects to the OLT
through a physical-layer transmission device, such as a switch, the physical-layer
transmission device supports untagged Ethernet packets (including IEEE 802.3ah OAM
and LACP packets) and transparently transmits the optical port status parameter.
l Only IPv4 management channel parameters can be configured.
Precautions
l Do not enable the remote software commissioning using PON upstream transmission.
l Ensure that the database of a newly deployed device is empty. Otherwise, the remote
software commissioning using GE upstream transmission cannot be used.
l On a network consisting of multiple cascaded devices, ensure that the upper-layer device
of a newly deployed device has been commissioned and can be logged in.
l Only the network management parameters defined in SNMPv1 and SNMPv2 are supported.
l When the ONU automatically obtains management parameters, it automatically generates
a default route that can be restored. However, the default route may not be proper in service
configuration. Therefore, you are advised to add a new route and delete the default one
after the ONU management channel is available.
l After the ONU automatically obtains management parameters, the remote software
commissioning function is automatically disabled if configurations are issued to the ONU
through the U2000. To modify the ONU management parameters, remotely log in to the
ONU through the command line interface (CLI).
Configuration requirements for the networking of OLT -> MA5603T:
l Do not remotely configure active/standby load-sharing on the MA5603T. Otherwise, the
management IP address of the MA5603T is deleted and you cannot remotely log in to the
MA5603T any more.
l If the MA5603T uses an SPUA board for upstream transmission, manual aggregation for
Ethernet ports cannot be configured on the OLT.
Configuration requirements for an OLT or ONU (an OLT is used as an example in the following
description) connected to an ONU through a link aggregation group (LAG):
l Neighbor automatic communication (NAC) can be configured only on the master port in
a LAG. When deploying a new device, ensure that the master port is correctly connected.
l The Link Aggregation Control Protocol (LACP) is recommended for an OLT LAG. For a
manual static LAG, during remote commissioning, run the shutdown command to disable
sub-ports in the LAG on the master node, manually configure a static LAG on the slave
node, and then run the undo shutdown command to enable the sub-ports in the LAG on
the master node.
l After the ONU goes online, remotely log in to the ONU and manually add a VLAN for the
master port and sub-ports in the LAG.
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
11 FTTB and FTTC Solution Configuration
Issue 01 (2014-04-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1027