User-bridging enable
-
IPoE VMAC NotConfig -
PPPoE VMAC NotConfig -
PPPoA VMAC NotConfig -
Mismatch IGMP packet policy discard
-
VMAC aging mode MAC-learning
-
OSPF tunnel enable
-
Layer-3 protocol tunnel enable
-
Mac-address learning fabric enable
-
DHCPv6 mode n/a -
DHCPv6 option enable -
PPPoA MAC mode NotConfig -
Anti-IPv6spoofing enable -
IPv6 DAD proxy disable -
Bind route and ND disable -
NS-reply function disable -
ARP-reply function disable -
DHCP relay-interface relay-agent NotConfig -
---------------------------------------------------------------------
Binding VLAN list : 0
---------------------------------------------------------------------
huawei(config)#vlan bind service-profile 101 profile-id 20
11. Configure queue scheduling.
The GOOSE service traffic is forwarded in PQ mode.
Queue scheduling is a global configuration. You need to configure queue scheduling only
once on the OLT, and then the configuration takes effect globally. In the subsequent phases,
you need not configure queue scheduling repeatedly when configuring other services.
huawei(config)#queue-scheduler strict-priority
Configure the mapping between queues and 802.1p priorities. Priorities 0-7 map queues
0-7 respectively.
For the service board that supports only four queues, the mapping between 802.1p priorities
and queue IDs is as follows: priorities 0 and 1 map queue 1; priorities 2 and 3 map queue
2; priorities 4 and 5 map queue 3; priorities 6 and 7 map queue 4.
huawei(config)#cos-queue-map cos0 0 cos1 1 cos2 2 cos3 3 cos4 4 cos5 5 cos6 6
cos7 7
12. Associated a protection group with an upstream Ethernet port.
huawei(config)#protect-group 0
huawei(protect-group-0)#uplink-monitor port 0/19/0
huawei(protect-group-0)#quit
NOTE
If an Ethernet link aggregation group is configured, the Ethernet port that is associated with the dual-
homing protection group must be the primary port in the aggregation group. Use the uplink-monitor
bfd command to associate the protection group with BFD sessions. For the configuration of BFD,
please refer to Configuring the BFD in OLT Configuration Guide.
13. Save the data.
huawei(config)#save
Step 2 The following describes the procedure for configuring the automatic transmission of site
information about the electrical power system over Ethernet on ONU_A.
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
17 Electrical Service Configuration
Issue 01 (2014-04-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1842