Parameter Description
Last Access Type Indicates the access type of the latest failed login.
Last IP-Address Indicates the IP address of the latest failed login.
Last Login Time Indicates the time of the latest failed login.
Login Failure Times Indicates the failed login times. It is the times of login failures
between two login successes, but not the accumulative login
failures.
All user fail login
information
Indicates the information about failed login of all users, which
can be viewed only by user root or security administrator.
Access Type Indicates the access type of the login.
IP-Address Indicates the IP address of the login.
Time Indicates the time of the login.
Login Times Indicates the login times.
----End
Result
After logging in to the system, you can maintain and manage the MA5600T/MA5603T/
MA5608T.
NOTE
To improve the system security, please modify your password after first login. You can run the terminal
user password command to modify your password.
Follow-up Procedure
l You can run the idle-timeout command to set the terminal timeout time. if you do not input
commands within the specified timeout time, the system disconnects the terminal. By
default, the terminal timeout time is set to 5 minutes. If you do not run any commands
within 5 minutes, the system disconnects with the terminal. To perform any operation, you
must have to log in to the system again.
l In the commissioning procedure, you must use the command, It is recommended that you
know well the command modes first.Figure 1-22 shows how to switch command modes.
Figure 1-22
huawei(config)#
huawei(config-if-...)
interface
quit
huawei#huawei>
enable
config
disable
quit
quit
return
Login
User mode
Privilege mode
Global config mode
Interface/config mode
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
1 Commissioning
Issue 01 (2014-04-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
37