Process 2: Station Catch Can Audit
Perform a system audit per the Irrigation Association’s (IA) Certified
Landscape Irrigation Auditor (CLIA) criteria. For information on the
CLIA program contact the Irrigation Association at:
www.irrigation.org
Process 3: Sprinkler Type Default
1. If the first two processes are not possible, then set the controller
to the default precipitation rate for each zone’s sprinkler type.
2. Process to use the defaults:
– In the programming process, select the sprinkler type for the
desired zone.
– Turn the Upper Line knob to set the precipitation rate.
– Do not change the default setting.
– Continue with programming the station.
Site Data Gathering