TroubleshooTing and sysTem TesTs
powermax
65/85
Service Manual 5-47
If the +48 VDC value is incorrect:
• Remove the fan connector (J3 for standard units or J5 for CE units) and repeat the test.
• If the value is now correct, replace the fan.
• If the value is still incorrect, replace the power board.
If the +3.3 VDC value is incorrect:
• Remove the fan connector (J3 CSA or J5 for CE units) and repeat the test.
• If the value is now correct, replace the fan.
• If value is still incorrect, remove the DSP board and repeat the test.
• If the value is now correct, replace the DSP board.
• If the value is still incorrect, replace the power board.
If the +5 VDC value is incorrect:
• Remove the pressure sensor connector (J5 CSA or J7 for CE units) and repeat the test.
• If the value is now correct, replace the pressure sensor.
• If the value is still incorrect, remove the DSP board and repeat the test.
• If the value is now correct, replace the DSP board.
• If the value is still incorrect, replace the power board.
If the +24 VDC value is incorrect:
• Remove the pressure switch connector (J1 CSA or J3 for CE units) and repeat the test.
• If the value is now correct, replace the pressure switch.
• If the value is still incorrect, replace the pressure switch connector, remove the solenoid valve connector
(J4CSA and J6 for CE units) and repeat the test. If the value is now correct, replace the solenoid valve. If the
value is still incorrect, replace the power board.

Table of Contents

Other manuals for Hypertherm Powermax 65

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 65 and is the answer not in the manual?

Hypertherm Powermax 65 Specifications

General IconGeneral
Open Circuit Voltage (OCV)300 VDC
Gas SupplyClean, dry, oil-free air or nitrogen
Maximum Cut Capacity (Mild Steel)1" (25 mm)
Input Voltage200-600 V, 1/3-PH, 50/60 Hz
Output Current20 – 65 A
Duty Cycle50% @ 65 A
Recommended Gas Inlet Flow Rate/Pressure6.7 scfm @ 85 psi
Torch Lead Length25 ft (7.6 m)
Maximum Cut Capacity (Aluminum)5/8" (16 mm)
Severance Cut Capacity (Mild Steel)1-1/4" (32 mm)
Maximum Severance Thickness1-1/4 in (32 mm)
Gas TypeAir/Nitrogen
Torch OptionsHand Torch, Mechanized Torch

Related product manuals