Parts
powermax
65/85
Service Manual 7-19
Machine torch consumables
Part number Description
Shielded
220817 Shield
220854 Retaining cap
220953 Ohmic retaining cap
220941 45 A Nozzle
220819 65 A Nozzle
220816 85 A Nozzle
220842 Electrode
220857 Swirl ring
Unshielded
220955 Deflector
220854 Retaining cap
220941 45 A Nozzle
220819 65 A Nozzle
220816 85 A Nozzle
220842 Electrode
220857 Swirl ring
Gouging
220798 65 A/85 A shield
220854 Retaining cap
220797 65 A/85 A nozzle
220842 Electrode
220857 Swirl ring
FineCut
1
220955 Deflector
220948 Shield
220854 Retaining cap
220953 Ohmic retaining cap
220930 Nozzle
220842 Electrode
220857 Swirl ring
1
The deflector (220955) is used only with the standard retaining cap (220854). The shield (220948) is used only with
the ohmic retaining cap (220953).

Table of Contents

Other manuals for Hypertherm Powermax 65

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 65 and is the answer not in the manual?

Hypertherm Powermax 65 Specifications

General IconGeneral
Open Circuit Voltage (OCV)300 VDC
Gas SupplyClean, dry, oil-free air or nitrogen
Maximum Cut Capacity (Mild Steel)1" (25 mm)
Input Voltage200-600 V, 1/3-PH, 50/60 Hz
Output Current20 – 65 A
Duty Cycle50% @ 65 A
Recommended Gas Inlet Flow Rate/Pressure6.7 scfm @ 85 psi
Torch Lead Length25 ft (7.6 m)
Maximum Cut Capacity (Aluminum)5/8" (16 mm)
Severance Cut Capacity (Mild Steel)1-1/4" (32 mm)
Maximum Severance Thickness1-1/4 in (32 mm)
Gas TypeAir/Nitrogen
Torch OptionsHand Torch, Mechanized Torch

Related product manuals