Page #198 background imageLoading...
Page #198 background image
Component ReplaCement
6-16 powermax
65/85
Service Manual
9. Temporarily remove the filter guide from the new air filter subassembly.
10. Place the subassembly into the rear panel hole.
11. Replace the three screws that hold the gas fitting to the rear panel. Torque down the screws to 15 in-lbs
(17.7kgcm).
12. Install the new filter guide onto the air filter subassembly.
13. Connect the gas supply hose to the air filter.
14. Connect the ground wire to the air filter body.
15. Connect the two wires to the top of the pressure switch.
16. Install the filter bowl onto the filter subassembly at the rear of the power supply. Refer to the instructions and figure
on page 6-14 Replace the air filter element.
17. Replace the power supply cover.
18. Reconnect the electrical power and the gas supply.

Table of Contents

Other manuals for Hypertherm Powermax 65

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 65 and is the answer not in the manual?

Hypertherm Powermax 65 Specifications

General IconGeneral
Open Circuit Voltage (OCV)300 VDC
Gas SupplyClean, dry, oil-free air or nitrogen
Maximum Cut Capacity (Mild Steel)1" (25 mm)
Input Voltage200-600 V, 1/3-PH, 50/60 Hz
Output Current20 – 65 A
Duty Cycle50% @ 65 A
Recommended Gas Inlet Flow Rate/Pressure6.7 scfm @ 85 psi
Torch Lead Length25 ft (7.6 m)
Maximum Cut Capacity (Aluminum)5/8" (16 mm)
Severance Cut Capacity (Mild Steel)1-1/4" (32 mm)
Maximum Severance Thickness1-1/4 in (32 mm)
Gas TypeAir/Nitrogen
Torch OptionsHand Torch, Mechanized Torch

Related product manuals