Torch SeTup
powermax
65/85
Service Manual 3-35
45A Shielded Air flow rate - slpm/scfh
Mild Steel
Hot 150 / 310
Cold 210/ 450
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce Delay
Time
Best Quality Settings Production Settings
Cut Speed Voltage Cut Speed Voltage
mm mm mm % seconds (mm/min) Volts (mm/min) Volts
0.5
1.5 3.8 250
0.0
9000 128 12500 126
1 9000 128 10800 128
1.5 0.1 9000 130 10200 129
2 0.3 6600 130 7800 129
3
0.4
3850 133 4900 131
4 2200 134 3560 131
6 0.5 1350 137 2050 132
English
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce Delay
Time
Best Quality Settings Production Settings
Cut Speed Voltage Cut Speed Voltage
in in % seconds ipm Volts ipm Volts
26GA
0.06 0.15 250
0.0
350 128 500 128
22GA 350 128 450 128
18GA
0.1
350 129 400 128
16GA 350 130 400 129
14GA 0.2 270 130 320 129
12GA
0.4
190 133 216 131
10GA 100 134 164 131
3/16 in 0.5 70 135 108 132
1/4 in 0.6 48 137 73 132

Table of Contents

Other manuals for Hypertherm Powermax 65

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 65 and is the answer not in the manual?

Hypertherm Powermax 65 Specifications

General IconGeneral
Open Circuit Voltage (OCV)300 VDC
Gas SupplyClean, dry, oil-free air or nitrogen
Maximum Cut Capacity (Mild Steel)1" (25 mm)
Input Voltage200-600 V, 1/3-PH, 50/60 Hz
Output Current20 – 65 A
Duty Cycle50% @ 65 A
Recommended Gas Inlet Flow Rate/Pressure6.7 scfm @ 85 psi
Torch Lead Length25 ft (7.6 m)
Maximum Cut Capacity (Aluminum)5/8" (16 mm)
Severance Cut Capacity (Mild Steel)1-1/4" (32 mm)
Maximum Severance Thickness1-1/4 in (32 mm)
Gas TypeAir/Nitrogen
Torch OptionsHand Torch, Mechanized Torch