Powermax30 XP Service Manual 808150 Revision 0 119
6 Power Supply Component Replacement
Replacing the drain hose, gas supply hoses, and 90° fitting
The Powermax30 XP contains a drain hose and two gas supply hoses that can be replaced. (See Figure 57.)
The drain hose runs from the bottom of the air filter bowl to the base of the power supply.
One gas supply hose runs from the air filter/regulator to the solenoid valve.
The other gas supply hose runs from the solenoid valve to the torch lead.
You can also replace the plastic 90° fitting that connects the gas supply hose from the solenoid valve to the gas supply
fitting from the torch lead.
The gas supply hoses in this system use push-to-connect fittings.
Figure 56 – How to use push-to-connect fittings
Kit number Description
228095 Kit: Hoses: drain hose, two gas supply hoses, elbow fitting
Push-to-Connect
To connect, push the hose into the fitting until it stops. Pull on the hose to verify that it is secure.
To release, push the fitting collet toward the fitting, and pull the hose away from the fitting.
1
2
3
Hose Collet O-ring
1
2
3

Table of Contents

Other manuals for Hypertherm Powermax30 XP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax30 XP and is the answer not in the manual?

Hypertherm Powermax30 XP Specifications

General IconGeneral
BrandHypertherm
ModelPowermax30 XP
CategoryWelding System
LanguageEnglish

Related product manuals