98 Powermax30 XP Service Manual 808150 Revision 0
6 – Power Supply Component Replacement
Replacing the power cord and strain relief
Remove the power cord and strain relief
CSA power cords
1. Complete the following procedures:
a. Set the power switch to OFF (O), disconnect the power cord from the power source, and disconnect the gas
supply.
b. See Remove the power supply cover on page 88.
c. See Remove the component barrier on page 90.
d. See Detach the rear panel on page 95.
2. Remove the black and white wires from the top of the power switch.
Figure 36
Kit number Description
228210 Kit: CSA power cord with NEMA twist lock-style 240 V / 20 A plug, 1-phase, 3.0 m
(10 feet)
228140 Kit: CE power cord, 1-phase, 3.0 m (10 feet) (plug not included)
428231 Kit: CCC power cord, 1-phase, 3.0 m (10 feet) (plug not included)
228143 Kit: Power cord strain relief