Powermax30 XP Service Manual 808150 Revision 0 97
6 Power Supply Component Replacement
Figure 35
Reattach the rear panel
1. Push the rear panel into the base to re-engage the snaps.
2. Verify the hole in the ground wire clip is aligned with the screw holes in the rear panel and the power supply. (See
Figure 35.)
3. Tighten the retaining screw with a torque setting of 8.1 kg-cm (7 inch-pounds). (See Figure 32 on page 95.)
4. Reconnect the ground wire to the ground wire clip.
5. Tighten the strain relief nut on the power cord.
6. Reconnect the gas supply and power cord, and set the power switch to ON (I).
1
2
1
Ground wire clip
2
Rear panel