30 Powermax30 XP Service Manual 808150 Revision 0
2 Power Supply Setup
Additional gas filtration
When site conditions introduce moisture, oil, or other contaminants into the gas line, use a three-stage coalescing
filtration system, such as the Eliminizer filter kit (128647) available from Hypertherm distributors. A three-stage filtering
system works as follows to clean contaminants from the gas supply.
Install the filtering system between the quick-disconnect coupler and the power supply.
WARNING!
The air filter bowl may explode if the gas supply pressure exceeds 9.3 bar (135 psi).
Gas supply Power supply
Oil vapor filterOil filterWater and particle filter