Quick Start Guide ~ RCON PROFINET IO Specification ~
p102
©2023 / IAI Corporation
STEP
STEP
STEP
Operation
Table
of
Contents
3
Perform home return for the actuator
Home
Moves to home side
Homing Complete
Homing Incomplete Status
Position data edit Window
The actuator starts home return motion.
(2)
Click [Exe] .
(1)
Green light on
Once the home-return operation completes in the normal
condition, the lamp showing the home-return status
should turn on in green.
(3)
(1)
Click
The home return speed cannot be changed. Increasing this speed may increase
the impact when the actuator operating part hits the mechanical end, which may
adversely affect the actuator mechanism in the long run or increase the error of
the home position.
Home-return operation starts
Home return complete
Actuator starts moving!
If battery-less absolute specification (option) is selected, the home return