Quick Start Guide ~ RCON PROFINET IO Specification ~
p11
©2023 / IAI Corporation
STEP
STEP
STEP
Wiring
Table
of
Contents
Caution When Linking SCON Extension Unit
The SCON connection unit is to be installed next to the gateway unit.
If the connection order is wrong, a communication error may occur.
Caution When Linking RCON-PS/RCON-SC
RCON-PS should be placed to the next on the right side of the 24V RCON
driver unit, or next on the right side of the gateway unit when there is no
24V RCON driver unit.
RCON-SC should be placed to the next on the right side of the RCON-PS.
The terminal unit should come to the next on the right side of the
RCON-SC.
RCON-PS2
The right of the
24V driver unit
RCON-SC
The right of the
RCON-PS2
RCON-GW-TRS
Terminal Unit
(Dedicated for next to RCON-SC)
Right end
(Terminal resistor)
Make sure the extension
unit always comes to the
next on the right side of the
RCON gateway unit in the
view from the front side.
Gateway Unit
Extension Unit
24V Driver Unit