EasyManua.ls Logo

IAI ssel

IAI ssel
497 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
412
Appendix
Axis-Specific Parameters
No Parameter name
Default value
(Reference)
Input range Unit Remarks
83 Absolute synchro slave-
axis initialization
cancellation
0 0 ~ 5 Valid only with a synchro slave axis.
84 Maximum synchronization
correction speed of
synchro slave axis
5 0 ~ 100 mm/sec Maximum travel speed for synchronization position
correction of slave axis. Valid only with a synchro slave axis.
* Note: Not limited by the safety speed.
85 Home-return
acceleration/deceleration
15 1 ~ 300 0.01 G
86 Zone 1 MAX 0 -99999999 ~
99999999
0.001 mm Valid only when MAX > MIN. * Must be inside the range for
at least 3 msec.
87 Zone 1 MIN 0 -99999999 ~
99999999
0.001 mm Valid only when MAX > MIN. * Must be inside the range for
at least 3 msec.
88 Zone 1 output number 0 0 ~ 899 Physical output port or global flag (Output is invalid if “0” is
input; multiple specification is invalid)
89 Zone 2 MAX 0 -99999999 ~
99999999
0.001 mm Valid only when MAX > MIN. * Must be inside the range for
at least 3 msec.
90 Zone 2 MIN 0 -99999999 ~
99999999
0.001 mm Valid only when MAX > MIN. * Must be inside the range for
at least 3 msec.
91 Zone 2 output number 0 0 ~ 899 Physical output port or global flag (Output is invalid if “0” is
input; multiple specification is invalid)
92 Zone 3 MAX 0 -99999999 ~
99999999
0.001 mm Valid only when MAX > MIN. * Must be inside the range for
at least 3 msec.
93 Zone 3 MIN 0 -99999999 ~
99999999
0.001 mm Valid only when MAX > MIN. * Must be inside the range for
at least 3 msec.
94 Zone 3 output number 0 0 ~ 899 Physical output port or global flag (Output is invalid if “0” is
input; multiple specification is invalid)
95 Zone 4 MAX 0 -99999999 ~
99999999
0.001 mm Valid only when MAX > MIN. * Must be inside the range for
at least 3 msec.
96 Zone 4 MIN 0 -99999999 ~
99999999
0.001 mm Valid only when MAX > MIN. * Must be inside the range for
at least 3 msec.
97 Zone 4 output number 0 0 ~ 899 Physical output port or global flag (Output is invalid if “0” is
input; multiple specification is invalid)
98 ~
99
For future expansion 0
100 (For expansion) 0
101 Allowable time to exceed
continuous-operation
enable torque
0 0 ~ 300 0 sec: Do not monitor the time during which the continuous-
operation enable torque is exceeded
(Main application version 0.17 or later)
102 ~
103
(For expansion) 0
104 Multi-slider near-miss
detection target axis
specification
OH OH ~
FFFFFFFFH
Bits 0 to 3: Axis number of the paired axis to perform near-
miss detection against (on the positive side of
the coordinate system of the applicable axis)
Bits 4 to 7: Axis number of the paired axis to perform near-
miss detection against (on the negative side of
the coordinate system of the applicable axis)
* This parameter must be input for the paired
axis, as well. (For the purpose of
convenience, the axis with the younger axis
number is deemed the main multi-slider axis
in the pair.)
* This parameter can be specified only for an
axis whose resolution characteristics are the
same as those of the applicable axis.
* With the SSEL controller, the multi-slider
near-miss detection function cannot be used if
the synchro specification is selected.
* If no adjacent slider is present on the
corresponding moving side of the coordinate
system of the applicable axis, set “0.”
(Main application version 0.12 or later)