Table
5.
Firmware
Error
Codes.
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
20FC
0030
Corrupted
power,
packaging,
and
cooling
device
VPD
format
in
the
SPCN
configuration
table.
1.
Check
for
system
firmware
updates.
2.
Replace
the
part
specified
by
the
location
code.
20FF
0001
Problem
with
VPD
1.
Replace
the
part
indicated
by
the
location
code.
2.
If
no
location
code
is
specified,
call
service
support.
2100
0xxx
SCSI
controller
fault
1.
Before
replacing
any
system
components,
refer
to
the
notes
in
error
code
21A00001.
2.
Replace
the
SCSI
device.
2101
0010
The
IDE
device
remained
busy
longer
than
time-out
period
allows.
1.
Retry
the
operation.
2.
Check
for
system
firmware
updates.
3.
Call
service
support.
2101
0011
Execution
of
the
command
by
the
IDE
CD-ROM
was
not
completed
within
the
allowed
time.
1.
Retry
the
operation.
2.
The
CD
in
the
IDE
CD-ROM
may
not
be
readable.
Try
another
CD.
2101
0012
Execution
of
the
ATA
command
by
the
IDE
CD-ROM
failed.
1.
Check
the
power
and
signal
connectors
going
to
the
IDE
CD-ROM.
2.
Retry
the
operation.
3.
The
CD
in
the
IDE
CD-ROM
may
not
be
readable.
Try
another
CD.
2101
0013
Bootable
media
is
missing
from
the
IDE
CD-ROM
Put
a
bootable
CD
in
the
IDE
CD-ROM
drive.
2101
0014
The
media
in
the
IDE
CD-ROM
drive
has
been
changed
1.
Retry
the
operation.
2.
Check
for
system
firmware
updates.
3.
Call
service
support
2101
0015
Packed
command
execution
by
the
IDE
CD-ROM
failed
1.
The
CD
in
the
IDE
CD-ROM
may
not
be
readable.
Try
another
CD.
2.
Check
for
system
firmware
updates.
3.
Call
service
support.
21A0
0001
Description:
SCSI
DASD
-
test
unit
ready
failed
-
hardware
error
Action:
Note:
1.
Before
replacing
any
system
components:
a.
Ensure
that
the
controller
and
each
device
on
the
SCSI
bus
is
assigned
a
unique
SCSI
ID.
b.
Ensure
SCSI
bus
is
properly
terminated.
c.
Ensure
SCSI
signal
and
power
cables
are
securely
connected
and
not
damaged.
2.
The
location
code
information
is
required
to
identify
the
ID
of
SCSI
device
failures
as
well
as
to
indicate
the
location
of
the
controller
to
which
the
device
is
attached.
Check
the
system
error
logs
to
determine
the
location
code
information
associated
with
the
error
code.
a.
Replace
the
SCSI
device.
b.
Replace
the
SCSI
cable.
c.
Replace
the
SCSI
controller.
Chapter
5.
Error
Code
to
FRU
Index
179

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM P 615 series and is the answer not in the manual?

IBM P 615 series Specifications

General IconGeneral
BrandIBM
ModelP 615 series
CategoryServer
LanguageEnglish

Related product manuals