Table 6. Service Processor Error Codes. (continued)
Error Code Description Action/ Possible Failing FRU
4B00F112 Call to Pager failed 1. Check modem connection and
modem configuration. Modem
configuration can be checked using
the service processor menus.
2. Remote system problem
3. Telephone line problem
4. Modem
5. Service processor card.
Location: U0.1-P1-X1
4B00F114 Service processor TOD failed Service processor card.
Location: U0.1-P1-X1
4B00F115 SPCN buffer in NVRAM full If this message persists, re-IPL to clear
logs and reset programs. If the problem
continues, call the support center for
assistance.
4B00F116 Call for SPCN error data failed 1. Check AIX error log
2. Run system diagnostics
4B00F117 Call for SPCN error data failed 1. Check AIX error log
2. Run system diagnostics
4B00F118 Internal service processor program
transfer failed (Get IPL mode)
If this message persists, re-IPL to clear
logs and reset programs. Additional
contributors to this condition include:
1. Loose or missing JTAG cable from
service processor to system rack
2. System rack (run diagnostics on
processors and memory)
3. Service processor card.
Location: U0.1-P1-X1
4. If the problem continues, call the
support center for assistance.
4B00F119 Internal service processor program
transfer failed (switch IPL mode)
If this message persists, re-IPL to clear
logs and reset programs. Additional
contributors to this condition include:
1. Loose or missing JTAG cable from
service processor to system rack
2. System rack (run diagnostics on
processors and memory)
3. Service processor card.
Location: U0.1-P1-X1
4. If the problem continues, call the
support center for assistance.