Table 6. Service Processor Error Codes. (continued)
Error Code Description Action/ Possible Failing FRU
4B00F11A Internal service processor program
transfer failed (copy side B to A)
This message appears only in service
processor error log. If this message
persists, re-IPL to clear logs and reset
programs. Additional contributors to this
condition include:
1. Loose or missing JTAG cable from
service processor to system rack.
2. System rack (run diagnostics on
processors and memory)
3. Service processor card.
Location: U0.1-P1-X1
4. If the problem continues, call the
support center for assistance.
4B00F11B Operator panel response failure If this message persists, re-IPL to clear
logs and reset programs. Additional
contributors to this condition include:
1. Service processor card.
Location: U0.1-P1-X1
2. Operator Panel
Location: U1.1-P1-L1
4B00F11D Flash update LID (I/O drawer SPCN
LID) replacement fault on all I/O
drawers.
This message appears only in the
service processor error log. If this
message persists, re-IPL to clear logs
and reset programs. Additional
contributors to this condition include:
1. Bad update image.
2. Loose or missing SPCN cables.
3. Service processor
Location: U0.1-P1-X1
4. I/O drawer planar(s)
5. System rack SPCN card Location
code: U1.1-P2-X1
4B00F11E Flash update LID (I/O drawer SPCN
LID) replacement fault on at least one
I/O drawer.
This message appears only in the
service processor error log. If this
message persists, re-IPL to clear logs
and reset programs. Additional
contributors to this condition include:
1. Bad update image.
2. Loose or missing SPCN cables
3. Service processor
Location: U0.1-P1-X1
4. I/O drawer planar
5. System rack SPCN card Location
code: U1.1-P2-X1