v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, “Parts listing, System x3550 M3 Types 4254 and 7944,” on page 159 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
v Go to the IBM support Web site at http://www.ibm.com/systems/support/ to check for technical
information, hints, tips, and new device drivers or to submit a request for information.
Error code Description Action
2018002 Option ROM resource allocation failure Informational message that some devices might not
be initialized.
1. If possible, rearrange the order of the adapters in
the PCI slots to change the load order of the
optional-device ROM code.
2. Run the Setup utility, select Startup Options, and
change the boot priority to change the load order
of the optional-device ROM code.
3. Run the Setup utility and disable some other
resources, if their functions are not being used, to
make more space available.
a. Select Startup Options, then Planar
Ethernet (PXE/DHCP) to disable the
integrated Ethernet controller ROM.
b. Select Advanced Functions, then PCI Bus
Control, then PCI ROM Control Execution to
disable the ROM of the adapter in the PCI
slots.
c. Select Devices and I/O Ports to disable any
of the integrated devices.
4. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Each adapter
b. (Trained service technician only) System
board
3xx0007 (xx
can be 00 -
19)
Firmware fault detected, system halted
1. Recover the server firmware to the latest level.
2. Undo any recent configuration changes, or clear
CMOS memory to restore the settings to the
default values (see “System-board switches and
jumpers” on page 18.
3. Remove any recently installed hardware.
3038003 Firmware corrupted
1. Run the Setup utility, select Load Default
Settings, and save the settings to recover the
server firmware.
2. (Trained service technician only) Replace the
system board.
3048005 Booted secondary (backup) UEFI Image Information only. The backup switch was used to boot
the secondary bank.
34 IBM System x3550 M3 Types 4254 and 7944: Problem Determination and Service Guide

Table of Contents

Other manuals for IBM System x3550 M3 Type 4254

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3550 M3 Type 4254 and is the answer not in the manual?

IBM System x3550 M3 Type 4254 Specifications

General IconGeneral
ProcessorIntel Xeon 5600 series
Max Processors2
MemoryUp to 192 GB DDR3
Form Factor1U Rack
ChipsetIntel 5520
Drive BaysUp to 4 hot-swap 2.5-inch SAS/SATA or SSD
RAID SupportRAID 0, 1, 10
Network InterfaceDual-port Gigabit Ethernet
Power Supply460W or 675W
Expansion Slots2 PCIe 2.0
WeightApproximately 17.24 kg (38 lbs)
Memory Slots18 (RDIMM) or 12 (UDIMM)