80070603-0701ffff Sensor [SensorElementName] has transitioned to non-recoverable.
Explanation: IMM has detected Voltage Regulator Error.
Severity: Error
Alert Category: Critical - Power
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0530
SNMP Trap ID: 4
Automatically notify Support: No
User response:
v CPU 1 VRD: Indicates a problem with either the voltage regulator for CPU1 or CPU 1 itself
v CPU 2 VRD: Indicates a problem with either the voltage regulator for CPU2 or CPU 2 itself
v DIMM 01-06 VRD: Indicates a problem with either the voltage regulator for DIMMs 1-6 or 1 or more of the
following components: DIMM1-DIMM6
v DIMM 07-12 VRD: Indicates a problem with either the voltage regulator for DIMMs 7-12 or 1 or more of the
following components: DIMM7-DIMM12
v DIMM 13-18 VRD: Indicates a problem with either the voltage regulator for DIMMs 13-18 or 1 or more of the
following components: DIMM13-DIMM18
v DIMM 19-24 VRD: Indicates a problem with either the voltage regulator for DIMMs 19-24 or 1 or more of the
following components: DIMM19-DIMM24
v MainBrd ENET VRD: Indicates a problem with either the voltage regulator for the onboard Ethernet or the 10Gb
add-in card
v MainBrd SAS VRD: Indicates a problem with either the voltage regulator for the onboard SAS or the RAID cache
card
v MainBrd VRD: Indicates a problem with a voltage regulator for the system board
v System VRD: Indicates a problem with either a voltage regulator for the system board or the microprocessor and
memory expansion tray
1. Check the IMM Web event log. This event may be a symptom of an earlier error.
2. Depending on the error perform the following steps.
For a CPU 1 VRD or CPU 2 VRD error:
1. Replace system board.
2. Replace affected microprocessor.
For a DIMM 01-06 VRD, DIMM 07-12 VRD, DIMM 13-18 VRD, or DIMM 19-24 VRD error:
1. Replace DIMM(s) associated with error.
2. Replace system board.
For a MainBrd ENET VRD error:
1. Replace the Dual-port 10Gb-T (copper) Ethernet Adapter or the Dual-port 10Gb SFP+ (fibre) Ethernet Adapter if
installed.
2. Replace system board.
For a MainBrd SAS VRD error:
1. Replace the RAID cache card if installed.
2. Replace system board.
For a MainBrd VRD error:
1. Replace system board.
For a System VRD error:
80070603-0701ffff
Appendix D. Integrated management module II (IMM2) error messages 425