Page #113 background image
7-4
Rev AA
Motor Volts Error
Power supply voltage
varies too much
Check the power supply
output
Faulty printer PCB Replace the main printer
PCB
Faulty Motor Check the motor and replace
if necessary
Printhead Volts
Error
Power supply voltage
varies too much
Check the power supply
output
Faulty printer PCB Replace the main printer
PCB
Printer Hand Not
Set
Flash memory is lost Use the CLARiTY
configuration CD
Motor Calibration
Required
Flash memory is lost Use the CLARiTY
configuration CD
Printhead
Resistance Not
Set
Flash memory is lost Set the resistance value from
the user interface
Webbing Error
Supply ribbon reel
eccentric (+1mm)
Replace the reel
End of Reel
Less than 20 meters of
ribbon remaining on reel
Replace the reel
Incorrect Reel
Size
Ribbon cores not fitted Try using a different reel
Incorrect roll width fitted Make sure that the software
reel width setting matches
the width of the reel that you
are using
Error
Message
Possible Causes Remedies
Table 7-1: Error Messages and Remedies (Continued)
ICE P
egasus Service Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ice PegasusHS and is the answer not in the manual?

Ice PegasusHS Specifications

General IconGeneral
BrandIce
ModelPegasusHS
CategoryPrinter
LanguageEnglish

Related product manuals