Rev AA 7-5
Printer is not
powered up
Power plug not fully
seated in the socket
Check and correct
Power not turned on at
the source or at the power
supply
Check and correct
Power cable not properly
connected to the printer
and power supply
Check and correct
Power supply voltage set
incorrectly
Check and correct
Check the 5 A fuse on the
CLARiTY unit
Check and correct (Refer
“Replacing the Mains Fuse”
on page 5-2
Blown Fuse Replace Fuse
CLARiTY
controller is not
powered up
Cable not properly
connected to the printer
and controller
Check and correct
Incorrect cable between
the printer and controller
Check and correct
Faulty controller unit Check unit and replace the
components as required
Printhead does
not move in and
out
Air supply disconnected Check and set air pressure
to 3 bar
Solenoid wiring or air
lines defective
Check and correct
Defective solenoid Check and correct
Printhead is jammed Turn the power off and move
the head out of its parked
position. See if the head is
free to move in and out on its
pivot assembly. If not, clear
the obstruction.
Error
Message
Possible Causes Remedies
Table 7-1: Error Messages and Remedies (Continued)
ICE P
egasus Service Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ice PegasusHS and is the answer not in the manual?

Ice PegasusHS Specifications

General IconGeneral
BrandIce
ModelPegasusHS
CategoryPrinter
LanguageEnglish

Related product manuals